M-Endo Anti-corrosion Medium for Coliform Detection in Water (250g)
M-Endo Anti-corrosion Medium is a selective culture medium designed for the detection of coliform bacteria in water samples using the membrane filtration method. It is widely used in microbiological water testing, ensuring reliable and consistent results.
Product Name: M-Endo Anti-corrosion Medium
Form: Dehydrated culture medium
Package Size: 250g per bottle
Storage Condition: Room temperature
Shelf Life: 3 years
Preparation Instructions
Weigh 5.19g of the medium and dissolve in 98ml of distilled or deionized water. Add 2ml of absolute ethanol. Heat the mixture until boiling, then immediately stop heating. Cool to below 45°C. Store at 2–10°C and use within 96 hours.